Hitachi Energy RTU500 Series

3 months ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 8.2
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Hitachi Energy
  • Equipment: RTU500 series
  • Vulnerabilities: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Validation of Specified Index, Position, or Offset in Input
2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to execute cross-site scripting or trigger a denial-of-service condition on the affected device.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

Hitachi Energy reports the following products are affected:

  • RTU500 series: Versions 12.0.1 to 12.0.14
  • RTU500 series: Versions 12.2.1 to 12.2.11
  • RTU500 series: Versions 12.4.1 to 12.4.11
  • RTU500 series: Versions 12.6.1 to 12.6.9
  • RTU500 series: Versions 12.7.1 to 12.7.6
  • RTU500 series: Versions 13.2.1 to 13.2.6
  • RTU500 series: Versions 13.4.1 to 13.4.3
3.2 VULNERABILITY OVERVIEW 3.2.1 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-79

A vulnerability exists in the webserver that affects the RTU500 series product versions listed above. A malicious actor could perform cross-site scripting on the webserver due to an RDT language file being improperly sanitized.

CVE-2023-5767 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.0 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:H/A:L).

A CVSS v4 score has also been calculated for CVE-2023-5767. A base score of 7.0 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:H/VA:L/SC:N/SI:N/SA:N).

3.2.2 Improper Validation of Specified Index, Position, or Offset in Input CWE-1285

A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed above. An incomplete or incorrectly received APDU frame layout may cause blocking on the link layer. The error is caused by endless blocking when reading incoming frames on the link layer with incorrect length information of APDU or delayed reception of data octets. Only the communication link of the affected HCI IEC 60870-5-104 is blocked. If the attack sequence stops, the communication to the previously attacked link stabilizes.

CVE-2023-5768 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.9 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2023-5768. A base score of 8.2 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).

3.2.3 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-79

A vulnerability exists in the webserver that affects the RTU500 series product versions listed above. A malicious actor could perform cross-site scripting on the webserver due to user input being improperly sanitized.

CVE-2023-5769 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.4 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N).

A CVSS v4 score has also been calculated for CVE-2023-5769. A base score of 5.1 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Switzerland
3.4 RESEARCHER

Hitachi Energy reported these vulnerabilities to CISA.

4. MITIGATIONS

Hitachi Energy recommend users take the following actions as well as following general mitigation measures:

  • RTU500 series Versions 12.0.1 - 12.0.14: Update to CMU Firmware Version 12.0.15
  • RTU500 series Versions 12.2.1 - 12.2.11: Update to CMU Firmware Version 12.2.12
  • RTU500 series Versions 12.4.1 - 12.4.11: Update to CMU Firmware Version 12.4.12
  • RTU500 series Versions 12.6.1 - 12.6.9: Update to CMU Firmware Version 12.6.10
  • RTU500 series Versions 12.7.1 - 12.7.6: Update to CMU Firmware Version 12.7.7
  • RTU500 series Versions 13.2.1 - 13.2.6: Update to CMU Firmware Version 13.2.7
  • RTU500 series Versions 13.4.1 - 13.4.3: Update to CMU Firmware Version 13.4.4 or 13.5.1

For more information see the associated Hitachi Energy PSIRT security advisory.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY
  • May 8, 2025: Initial Republication of Hitachi Energy Advisory 8DBD000176
CISA

Mitsubishi Electric CC-Link IE TSN

3 months ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 8.2
  • ATTENTION: Exploitable remotely
  • Vendor: Mitsubishi Electric
  • Equipment: CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY
  • Vulnerability: Improper Validation of Specified Quantity in Input
2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the affected products.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

The following versions of Mitsubishi Electric CC-Link IE TSN, a network controller, are affected:

  • CC-Link IE TSN Remote I/O module NZ2GN2S1-32D/32T/32TE/32DT/32DTE: Versions 09 and prior
  • CC-Link IE TSN Remote I/O module NZ2GN2B1-32D/32T/32TE/32DT/32DTE: Versions 09 and prior
  • CC-Link IE TSN Remote I/O module NZ2GNCF1-32D/32T: Versions 09 and prior
  • CC-Link IE TSN Remote I/O module NZ2GNCE3-32D/32DT: Versions 09 and prior
  • CC-Link IE TSN Remote I/O module NZ2GN12A4-16D/16DE: Versions 09 and prior
  • CC-Link IE TSN Remote I/O module NZ2GN12A2-16T/16TE: Versions 09 and prior
  • CC-Link IE TSN Remote I/O module NZ2GN12A42-16DT/16DTE: Versions 09 and prior
  • CC-Link IE TSN Remote I/O module NZ2GN2S1-16D/16T/16TE: Versions 09 and prior
  • CC-Link IE TSN Remote I/O module NZ2GN2B1-16D/16T/16TE: Versions 09 and prior
  • CC-Link IE TSN Analog-Digital Converter module NZ2GN2S-60AD4: Versions 07 and prior
  • CC-Link IE TSN Analog-Digital Converter module NZ2GN2B-60AD4: Versions 07 and prior
  • CC-Link IE TSN Digital-Analog Converter module NZ2GN2S-60DA4: Versions 07 and prior
  • CC-Link IE TSN Digital-Analog Converter module NZ2GN2B-60DA4: Versions 07 and prior
  • CC-Link IE TSN FPGA module NZ2GN2S-D41P01/D41D01/D41PD02: Version 01
  • CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-300/60: Versions 1.08J and prior
3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER VALIDATION OF SPECIFIED QUANTITY IN INPUT CWE-1284

A remote attacker could cause a denial-of-service (DoS) condition in the products by sending specially crafted UDP packets. The threat arises when the affected product does not receive a valid UDP packet within 3 seconds after receiving a specially crafted UDP packet from a remote attacker, necessitating a system reset of the product for recovery.

CVE-2025-3511 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.9 has been calculated; the CVSS vector string is (AV: N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2025-3511. A base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Japan
3.4 RESEARCHER

Mitsubishi Electric reported this vulnerability to CISA.

4. MITIGATIONS

Mitsubishi Electric recommends that users update to the following:

  • CC-Link IE TSN Remote I/O module NZ2GN2S1-32D/32T/32TE/32DT/32DTE: Versions 10 or later
  • CC-Link IE TSN Remote I/O module NZ2GN2B1-32D/32T/32TE/32DT/32DTE: Versions 10 or later
  • CC-Link IE TSN Remote I/O module NZ2GNCF1-32D/32T: Versions 10 or later
  • CC-Link IE TSN Remote I/O module NZ2GNCE3-32D/32DT: Versions 10 or later
  • CC-Link IE TSN Remote I/O module NZ2GN12A4-16D/16DE: Versions 10 or later
  • CC-Link IE TSN Remote I/O module NZ2GN12A2-16T/16TE: Versions 10 or later
  • CC-Link IE TSN Remote I/O module NZ2GN12A42-16DT/16DTE: Versions 10 or later
  • CC-Link IE TSN Remote I/O module NZ2GN2S1-16D/16T/16TE: Versions 10 or later
  • CC-Link IE TSN Remote I/O module NZ2GN2B1-16D/16T/16TE: Versions 10 or later
  • CC-Link IE TSN Analog-Digital Converter module NZ2GN2S-60AD4: Versions 08 or later
  • CC-Link IE TSN Analog-Digital Converter module NZ2GN2B-60AD4: Versions 08 or later
  • CC-Link IE TSN Digital-Analog Converter module NZ2GN2S-60DA4: Versions 08 or later
  • CC-Link IE TSN Digital-Analog Converter module NZ2GN2B-60DA4: Versions 08 or later
  • CC-Link IE TSN FPGA module NZ2GN2S-D41P01/D41D01/D41PD02: Versions 02 or later
  • CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-300/60: Versions 1.09K or later

Mitsubishi Electric recommends users take the following mitigation measures to minimize the risk of exploiting this vulnerability:

  • Use a firewall, virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required.
  • Use within a LAN and block access from untrusted networks and hosts through firewalls.
  • Restrict physical access to the affected products and the LAN to which they are connected.
  • Install anti-virus software on your PC that can access the product.

For more information, see Mitsubishi Electric advisory 2025-001.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity.

5. UPDATE HISTORY
  • May 8, 2025 - Initial Republication Mitsubishi Electric Advisory 2025-001
CISA

Optigo Networks ONS NC600

3 months 1 week ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 9.3
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Optigo Networks
  • Equipment: ONS NC600
  • Vulnerability: Use of Hard-coded Credentials
2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to establish an authenticated connection with the hard-coded credentials and perform OS command executions.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

The following versions of Optigo Networks ONS NC600 are affected:

  • ONS NC600: Versions 4.2.1-084 through 4.7.2-330
3.2 VULNERABILITY OVERVIEW 3.2.1 USE OF HARD-CODED CREDENTIALS CWE-798

In Optigo Networks ONS NC600 versions 4.2.1-084 through 4.7.2-330, an attacker could connect with the device's ssh server and utilize the system's components to perform OS command executions.

CVE-2025-4041 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-4041. A base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Canada
3.4 RESEARCHER

Tomer Goldschmidt of Claroty Team82 reported this vulnerability to CISA.

4. MITIGATIONS

Optigo Networks recommends users implement at least one of the following additional mitigations:

  • Use a dedicated NIC on the BMS computer and exclusively use the computer for connecting to OneView to manage your OT network configuration.
  • Set up a router firewall with a white list for the devices permitted to access OneView.
  • Connect to OneView via secure VPN.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY
  • May 6, 2025: Initial Publication
CISA

Milesight UG65-868M-EA

3 months 1 week ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 6.1
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Milesight
  • Equipment: UG65-868M-EA
  • Vulnerability: Improper Access Control for Volatile Memory Containing Boot Code
2. RISK EVALUATION

Successful exploitation of this vulnerability could allow any user with admin privileges to inject arbitrary shell commands.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

The following versions of UG65-868M-EA, an industrial gateway, are affected:

  • UG65-868M-EA: Firmware versions prior to 60.0.0.46
3.2 VULNERABILITY OVERVIEW 3.2.1 Improper Access Control for Volatile Memory Containing Boot Code CWE-1274

An admin user can gain unauthorized write access to the /etc/rc.local file on the device, which is executed on a system boot.

CVE-2025-4043 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:H/A:N).

A CVSS v4 score has also been calculated for CVE-2025-4043. A base score of 6.1 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:N/SC:N/SI:H/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: China
3.4 RESEARCHER

Joe Lovett of Pen Test Partners reported this vulnerability to CISA.

4. MITIGATIONS

Milesight released the latest firmware Version 60.0.0.46 for the UG65 gateway. Users can download the latest firmware from the Milesight download center.

Please contact Milesight technical support for more information about this issue and for instructions for installing the latest firmware.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Ensure that principles of least privilege are followed.
  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY
  • May 6, 2025: Initial Publication
CISA

BrightSign Players

3 months 1 week ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 8.5
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: BrightSign
  • Equipment: Brightsign Players
  • Vulnerabilities: Execution with Unnecessary Privileges
2. RISK EVALUATION

Successful exploitation of this vulnerability could allow for privilege escalation on the device, easily guessed passwords, or for arbitrary code to be executed on the underlying operating system.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

Products using the following versions of BrightSign OS are affected:

  • BrightSign OS series 4 players: Versions prior to v8.5.53.1
  • BrightSign OS series 5 players: Versions prior to v9.0.166
3.2 VULNERABILITY OVERVIEW 3.2.1 EXECUTION WITH UNNECESSARY PRIVILEGES CWE-250

BrightSign players running BrightSign OS series 4 prior to v8.5.53.1 or series 5 prior to v9.0.166 contain an execution with unnecessary privileges vulnerability, allowing for privilege escalation on the device once code execution has been obtained.

CVE-2025-3925 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-3925. A base score of 8.5 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Financial Services, Food and Agriculture, Healthcare and Public Health
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States
3.4 RESEARCHER

Adam Merrill, a member of the Adversarial Modeling and Penetration Testing (AMPT) team at Sandia National Laboratories, reported this vulnerability to CISA.

4. MITIGATIONS

BrightSign fixed CVE-2025-3925 in v8.5.53.1 (for series 4 players) and v9.0.166 (for series 5 players). Both of these have been released and available on the BrightSign download site.

BrightSign recommends the following security practices:

  • Change default passwords when the device is initially set up.
  • Disable the local DWS as described in "High Security settings".
  • Disable the SSH/telnet server when not being used - it is not enabled by default.
  • Devices should be located where an attacker does not have physical access to the device.
  • SD and USB ports can be disabled if not needed.

For more information, please contact BrightSign via their website.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY
  • May 6, 2025: Initial Publication
CISA

KUNBUS GmbH Revolution Pi

3 months 1 week ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 9.3
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: KUNBUS
  • Equipment: Revolution Pi
  • Vulnerabilities: Missing Authentication for Critical Function, Authentication Bypass by Primary Weakness, Improper Neutralization of Server-Side Includes (SSI) Within a Web Page
2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow attackers to bypass authentication, gain unauthorized access to critical functions, and execute malicious server-side includes (SSI) within a web page.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

The following versions of KUNBUS Revolution Pi are affected:

Revolution Pi OS Bookworm: Versions 01/2025 and earlier
Revolution Pi PiCtory: Versions 2.5.0 through 2.11.1
Revolution Pi PiCtory: Versions 2.11.1 and earlier

3.2 VULNERABILITY OVERVIEW 3.2.1 Missing Authentication for Critical Function CWE-306

KUNBUS Revolution Pi OS Bookworm 01/2025 is vulnerable because authentication is not configured by default for the Node-RED server. This can give an unauthenticated remote attacker full access to the Node-RED server where they can run arbitrary commands on the underlying operating system.

CVE-2025-24522 has been assigned to this vulnerability. A CVSS v3.1 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-24522. A base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.2 Authentication Bypass by Primary Weakness CWE-305

KUNBUS PiCtory versions 2.5.0 through 2.11.1 have an authentication bypass vulnerability where a remote attacker can bypass authentication to get access due to a path traversal.

CVE-2025-32011 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-32011. A base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.3 Improper Neutralization of Server-Side Includes (SSI) Within a Web Page CWE-97

KUNBUS PiCtory version 2.11.1 and earlier are vulnerable when an authenticated remote attacker crafts a special filename that can be stored by API endpoints. That filename is later transmitted to the client in order to show a list of configuration files. Due to a missing escape or sanitization, the filename could be executed as HTML script tag resulting in a cross-site-scripting attack.

CVE-2025-35996 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-35996. A base score of 8.5 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.4 Improper Neutralization of Server-Side Includes (SSI) Within a Web Page CWE-97

KUNBUS PiCtory version 2.11.1 and earlier are vulnerable to a cross-site-scripting attack via the sso_token used for authentication. If an attacker provides the user with a PiCtory URL containing an HTML script as an sso_token, that script will reply to the user and be executed.

CVE-2025-36558 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N).

A CVSS v4 score has also been calculated for CVE-2025-36558. A base score of 5.1 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing, Energy, Transportation Systems, Water and Wastewater Systems
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER

Adam Bromiley of Pen Test Partners reported these vulnerabilities to CISA.

4. MITIGATIONS

KUNBUS has identified the following specific mitigations that users can apply to reduce risk:

  • Update PiCtory package to version 2.12

The preferred method for updating to version 2.12 is accomplished through KUNBUS's management UI Cockpit. However, users can also download the update package here.

By end of April 2025, KUNBUS plans to release a new Cockpit plugin that helps the user to make configurations which are available in a graphical interface. In the meantime, it is recommended that users activate authentication. Please refer to this guide for help with activating authentication.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY
  • May 1, 2025: Initial Publication
CISA

Rockwell Automation ThinManager

3 months 2 weeks ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 8.7
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Rockwell Automation
  • Equipment: ThinManager
  • Vulnerabilities: Improper Restriction of Operations within the Bounds of a Memory Buffer, Incorrect Default Permissions
2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to escalate privileges and cause a denial-of-service condition.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

The following versions of ThinManager, a software management platform, are affected:

  • ThinManager: Version 14.0.0 and prior
3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119

A denial-of-service vulnerability exists in Rockwell Automation ThinManager. The software fails to adequately verify the outcome of memory allocation while processing Type 18 messages. If exploited, a threat actor could cause a denial of service on the target software.

CVE-2025-3618 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2025-3618. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).

3.2.2 INCORRECT DEFAULT PERMISSIONS CWE-276

A privilege escalation vulnerability exists in Rockwell Automation ThinManager. When the software starts up, files are deleted in the temporary folder causing the Access Control Entry of the directory to inherit permissions from the parent directory. If exploited, a threat actor could inherit elevated privileges.

CVE-2025-3617 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-3617. A base score of 8.5 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States
3.4 RESEARCHER

An anonymous researcher working with Trend Micro's Zero Day Initiative reported these vulnerabilities to CISA.

4. MITIGATIONS

Rockwell Automation encourages users to update ThinManager to v14.0.2 or later to mitigate CVE-2025-3617.

Rockwell Automation fixed CVE-2025-3618 in the following versions of ThinManager:

  • ThinManager v11.2.11
  • ThinManager v12.0.9
  • ThinManager v13.1.5
  • ThinManager v13.2.4
  • ThinManager v14.0.2
  • For information on how to mitigate security risks on industrial automation control systems, Rockwell Automation encourages users to implement their suggested security best practices to minimize the risk of the vulnerability.

For more information about these issues, please see the Rockwell Automation security advisory SD1727.

Stakeholder-Specific Vulnerability Categorization can be used to generate more environment-specific prioritization.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY
  • April 29, 2025: Initial Publication
CISA

Delta Electronics ISPSoft

3 months 2 weeks ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 8.4
  • ATTENTION: Low attack complexity
  • Vendor: Delta Electronics
  • Equipment: ISPSoft
  • Vulnerabilities: Stack-based Buffer Overflow, Out-of-bounds Write
2. RISK EVALUATION

Successful exploitation of these vulnerabilities could result in an attacker executing arbitrary code.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

The following versions of ISPSoft are affected:

  • ISPSoft: Versions 3.19 and prior
3.2 VULNERABILITY OVERVIEW 3.2.1 STACK-BASED BUFFER OVERFLOW CWE-121

Delta Electronics ISPSoft Versions 3.19 and prior are vulnerable to a stack-based buffer overflow vulnerability that could allow an attacker to leverage debugging logic to execute arbitrary code when parsing CBDGL files.

CVE-2025-22882 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-22882. A base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.2 OUT-OF-BOUNDS WRITE CWE-787

Delta Electronics ISPSoft Versions 3.19 and prior are vulnerable to an out-of-bounds write vulnerability that could allow an attacker to execute arbitrary code when parsing DVP files.

CVE-2025-22883 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-22883. A base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.3 STACK-BASED BUFFER OVERFLOW CWE-121

Delta Electronics ISPSoft Versions 3.19 and prior are vulnerable to a stack-based buffer overflow vulnerability that could allow an attacker to execute arbitrary code when parsing DVP files.

CVE-2025-22884 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-22884. A base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Taiwan
3.4 RESEARCHER

Zero Day Initiative reported these vulnerabilities to CISA.

4. MITIGATIONS

Delta Electronics recommends users to update to ISPSoft v 3.21 or later.

For more information, see Delta Electronics' advisory.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.

5. UPDATE HISTORY
  • April 29, 2025: Initial Publication
CISA
Checked
7 minutes 6 seconds ago
Subscribe to CISA.gov feed